Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Tob Control ; 18(2): 88-91, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19318534

RESUMO

AIM: To conduct a pilot randomised controlled trial of mobile phone-based smoking cessation support intervention for the UK population. DESIGN: Randomised controlled trial (txt2stop). SETTING: Community. PARTICIPANTS: 200 participants responding to radio, poster and leaflet-based promotions regarding the trial. MAIN OUTCOME MEASURES: The response rate for the outcome measures planned for the main trial. Participants' qualitative responses to open-ended questions about the intervention content. Secondary outcomes were the outcomes planned for the main trial including the point prevalence of self-reported smoking at 4 weeks and pooled effect estimate for the short-term results for the STOMP and txt2stop trials. RESULTS: The response rate at 4 weeks was 96% and at 6 months was 92%. The results at 4 weeks show a doubling of self-reported quitting relative risk (RR) 2.08 (95% CI 1.11 to 3.89), 26% vs 12%. The pooled effect estimate combining txt2stop and a previous New Zealand trial in the short term is RR 2.18 (95% CI 1.79 to 2.65). CONCLUSIONS: Mobile phone-based smoking cessation is an innovative means of delivering smoking cessation support, which doubles the self-reported quit rate in the short term. It could represent an important, but as yet largely unused, medium to deliver age-appropriate public health measures. The long-term effect of this mobile phone-based smoking cessation support will be established by a large randomised controlled trial currently in recruitment.


Assuntos
Telefone Celular , Promoção da Saúde/métodos , Consulta Remota/métodos , Abandono do Hábito de Fumar/métodos , Adulto , Feminino , Linhas Diretas , Humanos , Masculino , Projetos Piloto , Método Simples-Cego , Prevenção do Hábito de Fumar , Reino Unido
3.
Future Child ; 10(1): 53-82, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10911688

RESUMO

Health care providers have numerous opportunities to intervene with parents and children to promote child safety practices that reduce rates of unintentional injuries. These individual-level interventions may be delivered in a variety of settings such as physician offices, clinics, emergency departments, or hospitals. This article systematically reviews 22 randomized controlled trials (RCTs) that examined the impact of interventions delivered in the clinical setting on child safety practices and unintentional injuries. The results indicate that counseling and other interventions in the clinical setting are effective at increasing the adoption of some safety practices, but not others. Specifically, motor vehicle restraint use, smoke alarm ownership, and maintenance of a safe hot tap water temperature were more likely to be adopted following interventions in the clinical setting. Clinical interventions were not proven effective at increasing a variety of safety practices designed to protect young children from injuries in the home, increasing bicycle helmet use, or reducing the occurrence of childhood injuries, though few studies examined the latter two outcomes. Clinical interventions were most effective when they combined an array of health education and behavior change strategies such as counseling, demonstrations, the provision of subsidized safety devices, and reinforcement. The article concludes with implications for research and practice.


Assuntos
Promoção da Saúde , Segurança , Ferimentos e Lesões/prevenção & controle , Criança , Instalações de Saúde , Humanos , Avaliação de Processos e Resultados em Cuidados de Saúde , Consultórios Médicos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
4.
J Thorac Cardiovasc Surg ; 115(1): 94-102, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9451051

RESUMO

OBJECTIVE: A novel noninvasive method for repeatedly measuring cerebral blood flow during cardiopulmonary bypass by near-infrared spectroscopy is described. The reproducibility of the method is investigated and a comparison is made with an established technique. METHODS AND RESULTS: The method is derived from the Fick principle and uses indocyanine green dye, injected into the bypass circuit, as an intravascular tracer. Cerebral blood flow was measured in nine children undergoing cardiopulmonary bypass on a total of 49 occasions. Results from this study suggest that an integrating period of 4 seconds provided a consistent measurement of global cerebral blood flow. The values obtained ranged from 3.2 to 32.4 (median 15.9) ml.100 gm-1.min-1. In an additional 10 children in whom repeated measurements were made, the coefficient of variation was 11% +/- 7% (mean +/- standard deviation). In a further study, the method was compared with microsphere injection in five piglets undergoing cardiopulmonary bypass. The comparison within each animal with the linear least squares method gave values for R2 in the range 0.91 to 0.99. The gradients of the fits ranged from 0.5 to 1.8 (median 1.0). The mean difference between the two techniques was 5.7 ml.100 gm-1.min-1 or 7%. The coefficient of variation for the piglets was 14% +/- 9% (mean +/- standard deviation). CONCLUSIONS: Indocyanine green and near-infrared spectroscopy allow frequent and repeated measurements of cerebral blood flow during cardiopulmonary bypass. The measurements are reproducible and accurately reflect changes in cerebral blood flow. It may be widely applicable both in research and clinical practice.


Assuntos
Ponte Cardiopulmonar , Circulação Cerebrovascular/fisiologia , Animais , Animais Recém-Nascidos , Criança , Pré-Escolar , Corantes , Humanos , Verde de Indocianina , Lactente , Microesferas , Monitorização Intraoperatória/métodos , Reprodutibilidade dos Testes , Espectroscopia de Luz Próxima ao Infravermelho , Suínos
5.
J Thorac Cardiovasc Surg ; 114(4): 568-77, 1997 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9338642

RESUMO

OBJECTIVES: Neurologic impairment, at least partly ischemic in origin, has been reported in up to 25% of infants undergoing cardiopulmonary bypass, with or without circulatory arrest. Controversy continues about the effect of pump flow, pulsatile or nonpulsatile, on the brain and in particular on cerebral blood flow. This study examines the relationship between pump flow rate and cerebral hemodynamics during pulsatile and nonpulsatile cardiopulmonary bypass. METHOD: Near-infrared spectroscopy was used to determine cerebral blood flow and cerebral blood volume (measured as concentration change) in a randomized crossover study. Pulsatile and nonpulsatile flow were used for six 5-minute intervals at each of three different pump flow rates (0.6, 1.2, and 2.4 L x m2 x min(-1)) in 40 patients, median age 2 months (range 2 weeks to 20 years 5 months). The relations between pulsatile flow, pump flow rate, cerebral blood flow, hemoglobin concentration change (cerebral blood volume), mean arterial pressure, arterial carbon dioxide tension, and hematocrit value were prospectively examined by means of multivariate analysis. RESULTS: Cerebral blood flow decreased 36% per L x m(-2) x min(-1) decrease in pump flow rate and was associated with changes in mean arterial pressure but did not differ according to pulsatility. Change in hemoglobin concentration was unrelated to changes in pulsatility of pump flow. CONCLUSION: Cerebral blood flow is related to pump flow rate. Pulsatile flow delivered with a Stöckert pump does not increase cerebral blood flow or alter hemoglobin concentration during cardiopulmonary bypass in children.


Assuntos
Ponte Cardiopulmonar/métodos , Circulação Cerebrovascular/fisiologia , Fluxo Pulsátil , Volume Sanguíneo/fisiologia , Ponte Cardiopulmonar/instrumentação , Estudos Cross-Over , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Modelos Lineares , Espectroscopia de Luz Próxima ao Infravermelho
6.
Eur J Cardiothorac Surg ; 11(4): 633-9, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9151029

RESUMO

OBJECTIVES: Neurological impairment occurs in up to 25% of infants undergoing cardiopulmonary bypass with or without circulatory arrest. Potential causes include alterations in cerebral blood flow, hypoxia and embolisation. During cardiopulmonary bypass, arterial oxygen tension is maintained at levels which under normal conditions cause cerebral vasoconstriction; this is a potential mechanism for ischaemia. The aim of this study was to explore the relation between arterial oxygen tension and cerebral blood flow during cardiopulmonary bypass. METHODS: Near infrared spectroscopy was used to explore the relation between arterial oxygen tension and cerebral blood flow in 14 patients (median age 8 months; range 1 month to 10 years 11 months). The relations between arterial oxygen tension, arterial carbon dioxide tension, temperature, haematocrit, pump flow rate, mean arterial pressure and cerebral blood flow, were examined using multivariate analysis. RESULTS: There was no relation between cerebral blood flow and arterial oxygen tension, but a highly significant relation was observed between cerebral blood flow and pump flow rate, with cerebral blood flow decreasing 4.2-fold per L.m-2.min-1 decrease of pump flow rate. CONCLUSION: There was no relation between arterial oxygen tension and cerebral blood flow during cardiopulmonary bypass, but low pump flow rate may lead to reduced cerebral blood flow.


Assuntos
Isquemia Encefálica/fisiopatologia , Encéfalo/irrigação sanguínea , Ponte Cardiopulmonar , Cardiopatias Congênitas/cirurgia , Oxigênio/sangue , Velocidade do Fluxo Sanguíneo/fisiologia , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/fisiopatologia , Humanos , Hipóxia Encefálica/fisiopatologia , Lactente , Complicações Intraoperatórias/fisiopatologia , Masculino , Fluxo Sanguíneo Regional/fisiologia , Fatores de Risco , Vasoconstrição/fisiologia
7.
Perfusion ; 12(2): 113-9, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9160362

RESUMO

There is evidence that during cardiopulmonary bypass (CPB), pulsatile pump flow improves cerebral metabolism. This was a study to explore the effect of pulsatile versus nonpulsatile perfusion on cerebral lactate, pyruvate, glucose and beta-hydroxybutyrate using a Stöckert roller pump. We found no significant differences between the arterial-venous (A-V) differences of lactate, glucose and beta-hydroxybutyrate (p > 0.05). When the upward trend of A-V pyruvate was accounted for, there was again no difference (p = 0.2). Arterial lactate:pyruvate ratios were not significantly different between pulsatile and nonpulsatile pump flow (p > 0.05). Venous lactate:pyruvate ratios were significantly higher during pulsatile bypass, but when the downward trend was accounted for, the differences between pulsatile and nonpulsatile values were no longer significant (p = 0.4). Therefore, the metabolic changes were not significant. There was no significant difference in systemic vascular resistance (SVR) during pulsatile and nonpulsatile flow (p = 0.4). Pulsatile flow delivered by the Stöckert roller pump appears to have no metabolic or SVR advantages in adults undergoing CPB.


Assuntos
Encéfalo/metabolismo , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/instrumentação , Circulação Cerebrovascular , Fluxo Pulsátil , Ácido 3-Hidroxibutírico , Adulto , Idoso , Glicemia/análise , Química Encefálica , Ponte de Artéria Coronária , Desenho de Equipamento , Humanos , Hidroxibutiratos/sangue , Ácido Láctico/sangue , Masculino , Pessoa de Meia-Idade , Ácido Pirúvico/sangue , Resistência Vascular
8.
Magn Reson Med ; 36(3): 366-74, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8875406

RESUMO

Divergencies between chemical shift measurements of temperature and directly measured values using optical sensors have been studied in vivo in human peripheral muscle with the assistance of a variety of experimental and theoretical techniques. These include the modelling of both thermal and susceptibility changes using two- and three-dimensional finite element methods, as well as the use of multi-wavelength near-infrared observations. The conclusion of these studies is that a simple temperature calibration is not accessible, with results affected by the complex response of the tissue itself.


Assuntos
Músculos/metabolismo , Temperatura , Água/química , Humanos , Modelos Estruturais , Espectroscopia de Luz Próxima ao Infravermelho
9.
J Paediatr Child Health ; 30(3): 220-3, 1994 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8074907

RESUMO

The authors used data from the New Zealand Household Travel Survey to examine the extent to which children's pedestrian exposure varies with age, sex and household income. Pedestrian injury morbidity data were combined with pedestrian exposure data to examine age-specific pedestrian injury risk. The annual number of road crossings for girls was greater than that for boys. Pedestrian exposure increased with increasing age. Children aged 5-9 years in the lowest household income bracket crossed approximately 50% more roads than those in the middle and upper income brackets. However, for children aged 10-14 years there was little variation with household income. Sex differences in pedestrian injury rates cannot be explained by differences in exposure although increased exposure may partly explain the increased injury rates for children in lower socio-economic groups. Prevention strategies might aim to reduce pedestrian exposure for alternatively to reduce pedestrian injury risk per unit of exposure by making safer urban living environments.


Assuntos
Acidentes de Trânsito/estatística & dados numéricos , Exposição Ambiental , Viagem/estatística & dados numéricos , Ferimentos e Lesões/epidemiologia , Ferimentos e Lesões/etiologia , Acidentes de Trânsito/prevenção & controle , Adolescente , Criança , Pré-Escolar , Análise por Conglomerados , Coleta de Dados , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Renda , Masculino , Morbidade , Nova Zelândia/epidemiologia , Fatores de Risco , Fatores Sexuais , Ferimentos e Lesões/prevenção & controle
10.
Eur J Cardiothorac Surg ; 8(3): 130-4, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-8011345

RESUMO

Neurological impairment may occur following cardiopulmonary bypass (CPB) and the effect of CPB on cerebrovascular control may be important in the mechanism of cerebral injury. We have used near infrared spectroscopy (NIRS) to observe cerebral haemodynamics non-invasively before and during CPB. We measured the change in cerebral blood volume (CBV) associated with changing PaCO2 (CBVR). Patients (n = 19) were aged from 1 to 135 (median 14) months. The cerebral blood volume response was determined pre-operatively at normothermia under the influence of standardised anaesthesia employing isoflurane (up to ET conc 0.5%) and during steady-state hypothermic bypass (22-32 degrees C) at an arterial pump flow rate of 1.9-2.4 lm-2.min-1. Complete data was available for 10 patients. The relation between CBV, arterial carbon dioxide tension (PaCO2), mean arterial pressure (MAP) and central venous pressure (CVP) was examined using analysis of covariance (P < or = 0.05) was accepted as significant). The change in CBV associated with changing PaCO2 was corrected for the effects of MAP and CVP. Preoperatively the median CBVR was 0.130 (25th-75th percentile 0.079-0.243) ml.100 g-1.kPa-1 and during hypothermic bypass the median CBVR was 0.093 (25th-75th percentile 0.026-0.255) ml.100 g-1.kPa-1. These values were compared with our reference range derived for normal conscious children using the Kruskal-Wallis test. There was not statistically significant difference between the three groups (P = 0.35). These results, indicating preservation of CBVR during the conditions of anaesthesia and bypass used, are consistent with the observations of previous authors who measured cerebral blood flow response to carbon dioxide by a variety of other methods. Near infrared spectroscopy is proving to be a reliable, non-invasive technique for the investigation of cerebral haemodynamics during CPB.


Assuntos
Volume Sanguíneo , Dióxido de Carbono/sangue , Ponte Cardiopulmonar , Circulação Cerebrovascular , Adolescente , Ponte Cardiopulmonar/efeitos adversos , Criança , Pré-Escolar , Cardiopatias Congênitas/sangue , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Recém-Nascido , Pressão Parcial , Espectrofotometria Infravermelho
11.
Arch Dis Child ; 68(2): 190-2, 1993 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8481041

RESUMO

Trends in pedestrian injury mortality for children aged 0-4 and 5-14 for England and Wales, Denmark, Sweden, the USA, and New Zealand were examined from 1968 onwards. While there has been a reduction in the pedestrian mortality in all these countries, there are striking international differences in the extent of these reductions. Denmark has achieved the greatest fall in mortality with the smallest decrease seen in New Zealand. Countries which have experienced major decreases in pedestrian mortality are distinguished by having placed greater emphasis on environmentally based prevention strategies rather than pedestrian skills education.


Assuntos
Acidentes de Trânsito/tendências , Acidentes de Trânsito/mortalidade , Adolescente , Fatores Etários , Criança , Pré-Escolar , Dinamarca , Inglaterra , Humanos , Lactente , Recém-Nascido , Nova Zelândia , Suécia , Estados Unidos , País de Gales , Ferimentos e Lesões/mortalidade
12.
Neurosci Lett ; 150(1): 9-12, 1993 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-8469408

RESUMO

Area V4 has been located in man in the region of the fusiform gyrus on the inferior surface of the occipital lobe. Using multiple dipole source analysis on multichannel EEG recordings of visual evoked potentials to coloured 'Mondrian' stimuli in man, we have confirmed that activity is consistently seen in this area regardless of the retinal area stimulated and have obtained new information concerning its time course. Three different localized centres of activity follow the visual stimulus, with peak latencies of 90, 110 and 160 ms, and arising respectively in the region of visual areas V1, V2/V3 and V4. The time course and character of the V4 dipole activity to a colourless black-and-white Mondrian is indistinguishable from that to the coloured Mondrian, supporting the evidence that the cells of V4 are not exclusively concerned with colour processing.


Assuntos
Percepção de Cores/fisiologia , Potenciais Evocados Visuais , Lobo Occipital/fisiologia , Mapeamento Encefálico , Eletroencefalografia , Potenciais Evocados , Feminino , Humanos , Masculino , Fatores de Tempo , Visão Binocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...